Tools, Technologies and Training for Healthcare Laboratories

Siriraj Piyamaharajkarun Hospital Sigma Verification of Performance

Siriraj Piyamaharajkarun Hospital (SiPH) has joined the Westgard Sigma Verification of Performance. Verified since 2015. Consistently growing from 40, 50, 60, 70, 80 and now over 90 methods verified.

Siriraj Piyamaharajkarun Hospital (SiPH) - Sigma Verification of Performance

Duration of Current Verification: February 2, 2022 through February 28, 2023
Verified since 2015, original verification December 15, 2015.

In February, Westgard QC was happy to re-verify the performance of more than 80 assays at SiPH in chemistry, immunoassay, and urine assays.

 SiPH, Bangkok, Thailand

For over 120 years of King Chulalongkorn’s kindheartedness provided the establishment of a hospital that acts as a “giver” to treat illnesses and promote happiness for all Thai people. From the past to the present, the Faculty of Medicine Siriraj Hospital has never ceased to continue his aspiration to be the provider of a new alternative medical service with the concept of individuals being both “recipient” and “giver” at the same time.  Siriraj Piyamaharajkarun Hospital has medical standards that meet international levels regarding treatment, management and a service that provides a good standard of life of all Thai people.

http://www.siphhospital.com/en/about-us/history.html

Performance of SiPH

Chemistry Assays

C1601955 Verified

C1601967 Verified

Albumin

Six Sigma

Six Sigma

Alk Phos

-

Six Sigma

ALT

Six Sigma

Six Sigma

AST

Six Sigma

Six Sigma

Amylase

-

Six Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Bilirubin, Total

Six Sigma

Six Sigma

C-Reactive Protein

-

Six Sigma

Calcium

-

Six Sigma

Chloride

Six Sigma

Six Sigma

Cholesterol

Six Sigma

Six Sigma

Creatinine

Six Sigma

Six Sigma

Creatinine Kinase (CK)

-

Six Sigma

CO2

Six Sigma

Six Sigma

GGT

-

Six Sigma

Glucose

Six Sigma

Six Sigma

HDL

Six Sigma

Six Sigma

Iron

-

Six Sigma

LDH

-

Six Sigma

LDL

Six Sigma

Six Sigma

Lactate

Six Sigma

-

Magnesium

-

Six Sigma

Phosphorous

-

Six Sigma

Potassium

Six Sigma

Six Sigma

Protein, Total

Six Sigma

Six Sigma

Sodium

Six Sigma

Six Sigma

Triglycerides

Six Sigma

Six Sigma

UIBC

-

Five Sigma

Urea Nitrogen

Five Sigma

Six Sigma

Uric Acid

Six Sigma

Six Sigma

In addition to biochemistry assays, immunoassays were re-verified.

Immunoassays

iSR08406 Verified

iSR63724 Verified

iSR63726 Verified

25-OH Vitamin D

-

Six Sigma

Six Sigma

AFP

-

Six Sigma

Six Sigma

CEA

-

Four Sigma

Five Sigma

Cortisol

-

Six Sigma

-

Estradiol

Six Sigma

-

-

Folate

Five Sigma

-

-

FSH

Six Sigma

-

-

LH

Six Sigma

-

-

Phenytoin

Six Sigma

-

-

Prolactin

Six Sigma

-

-

PSA

-

Six Sigma

Six Sigma

T3, Total

-

Six Sigma

Six Sigma

T4, Free

-

Four Sigma

-

T4, Total

-

Five Sigma

-

TSH

-

Six Sigma

Six Sigma

Vancomycin

Six Sigma

-

-

In addition, urine assays were re-verified:

Urine assays

C1601967 Verified

Albumin, U

Six Sigma

Calcium, U

Six Sigma

Chloride, U

Six Sigma

Creatinine, U

Six Sigma

Glucose, U

Six Sigma

Magnesium , U

Six Sigma

Phosphate, U

Six Sigma

Potassium, U

Six Sigma

Protein, U

Six Sigma

Sodium, U

Six Sigma

Urea, U

Six Sigma

Uric, U

Six Sigma

 

Visual Display of SiPH Sigma performance

 2022 SiPH re vp Sigma Decision Chart 1

2022 SiPH re vp Sigma Decision Chart 2

2022 SiPH re vp Sigma Decision Chart 3

2022 SiPH re vp Sigma Decision Chart 4

2022 SiPH re vp Sigma Decision Chart 5

2022 SiPH re vp Sigma Decision Chart 6

 

  SiPH presentation Sigma VP 2015

Original verification ceremony 2015

 Congratulations to SiPH for their continuing, expanded dedication to quality and their continued accomplishments.

Let us know what you're interested in!
Please use this form to request more infromation about 

Westgard Products and Services.

Invalid Input
Invalid Input
Invalid Input
Invalid Input