Tools, Technologies and Training for Healthcare Laboratories

Min-Sheng General Hospital Sigma Verification of Performance

The laboratory of Min-Sheng General Hospital in Taoyuan, Taiwan has joined the Sigma Verification of Performance program

Sigma Verification of Clinical Laboratory of Min-Sheng General Hospital

Verification: January 1st, 2020
Duration of Verification: January 1st, 2020 through January 31st, 2021

 In 2020, Min-Sheng General Hospital joined the Westgard Sigma Verification of Performance Program.

From their website:

 "Min-Sheng General Hospital is the flagship hospital of the Missioncare group. Located close to Taiwan’s main International Airport, this 600-bed hospital provides comprehensive tertiary health care and specializes in minimally invasive surgical procedures; its bariatric, spine, and cardiac surgery centers have achieved international recognition. The hospital boasts the latest in medical technology, and is at the forefront of the integration of information technology in health care delivery in Taiwan.

"Min-Sheng General Hospital recruits physicians from Taiwan’s top medical schools, and eighty-five percent of its doctors are National Taiwan University graduates. Striving for excellence, Min-Sheng General Hospital actively seeks third party validation of its facilities, and processes. In 2006 it received international recognition for its patient centered, evidence based care by becoming the first hospital in Taiwan to be accredited by JCI, the international arm of Joint Commission, the body that certifies all hospitals in the USA. Min-Sheng General Hospital has also received JCI certification for its Acute Myocardial Infarction (AMI), Diabetes type II, and Chronic Kidney Disease programs."

Summary of Analyte Performance

Instruments in Hematology, Chemistry, Immunoassay and Urine were verified.

Hematology Assay

XE-5000A

Hemoglobin

Six Sigma

MVC

Six Sigma

MCH

Six Sigma

MCHC

Four Sigma

Platelets

Four Sigma

RBC

Five Sigma

WBC

Five Sigma

Lymphocytes

Four Sigma

Monocytes

Four Sigma

Eosinophils

Four Sigma

Basophils

Six Sigma

Neutrophils

Six Sigma

Chemistry assays were also verified

Chemistry Assay

 CI 16200 B

Albumin

Four Sigma

Alkaline Phosphatase

Six Sigma

Amylase

Six Sigma

AST

Six Sigma

Bilirubin, Direct

Six Sigma

Bilirubin, Total

Six Sigma

C- Reactive protein

Six Sigma

Calcium

Five Sigma

Chloride

Six Sigma

Cholesterol

Six Sigma

Creatinine Kinase (CK)

Six Sigma

Creatinine

Six Sigma

GGT

Six Sigma

Glucose

Six Sigma

Iron

Six Sigma

HDL

Six Sigma

LDL

Six Sigma

LDH

Five Sigma

Lipase

Four Sigma

Magnesium

Six Sigma

Phosphorous

Five Sigma

Potassium

Six Sigma

Sodium

Five Sigma

Total Protein

Six Sigma

Triglycerides

Six Sigma

UIBC

Five Sigma

Urea Nitrogen

Five Sigma

Uric Acid

Six Sigma

 Immunoassays were also verified:

Immunoassays

ci8200 A ia

Ci16200 B ia

AFP

Four Sigma

Four Sigma

Cortisol

Six Sigma

-

Ferritin

-

-

Folate

Six Sigma

-

PSA

-

Six Sigma

TSH

Four Sigma

Four Sigma

Vitamin B12

Five Sigma

 

  Six Sigma: World Class Quality. Possible to use 3s to 3.5s limits and a minimum of controls

Five Sigma: Excellent Quality. Possible to use 3s limits or a 1:3s/2:2s/R:4s Westgard Rule

Four Sigma: Good Quality. Possible to use 1:3s/2:2s/R:4s/4:1s Westgard Rule

 Visual Summary of Performance of Min-Sheng Hospital Lab

2020 vp Min Sheng medx 1

2020 vp Min Sheng medx 2

 2020 vp Min Sheng medx 3

 Congratulations again to Min-Sheng General Hospital and their staff.

 

 

 

 

Let us know what you're interested in!
Please use this form to request more infromation about 

Westgard Products and Services.

Invalid Input
Invalid Input
Invalid Input
Invalid Input