Tools, Technologies and Training for Healthcare Laboratories

Loh Guan Lye Sigma Verification of Performance

Loh Guan Gye Laboratory has succeeded in its latest re-verification.

Sigma Verification of the Loh Guan Gye

Verified since 2016
Re-Verification: December 12th, 2017
Duration of Verification: December 12th, 2017 through January 1st, 2019 

From the Loy Guan Lye website:

"LohGuanLye SPECIALISTS CENTRE (LSC), established in 1975, is a 273 bedded private hospital. It is located in the heart of Georgetown, Penang, about 30 minutes from the Penang International Airport and 20 minutes from the pristine beaches at Batu Ferringhi. The Centre provides a very comprehensive and quality healthcare services and facilities ranging from prevention, diagnosis and treatment of a wide range of diseases and medical conditions to cosmetic procedures and health screening packages in a warm and caring environment ideal for rest and recovery."

The following assays and instruments which were verified

Analyte

c8000 A  verified performance

c8000 B  verified performance

Albumin

Four Sigma

Four Sigma

Alkaline Phosphatase

 

Six Sigma

Amylase

 

Six Sigma

ALT

Six Sigma

Six Sigma

AST

Six Sigma

Six Sigma

Bilirubin, Direct

Six Sigma

Six Sigma

Bilirubin, Total

Six Sigma

Six Sigma

Calcium

Six Sigma

Six Sigma

Chloride

Five Sigma

Four Sigma

Cholesterol, total

Six Sigma

Six Sigma

Cholesterol, HDL

 

Six Sigma

Creatinine

Six Sigma

Six Sigma

GGT

Six Sigma

Six Sigma

Glucose

Six Sigma

Six Sigma

LDH

Six Sigma

Six Sigma

Phosphorous

Six Sigma

Five Sigma

Potassium

Six Sigma

Six Sigma

Sodium

 

Five Sigma

Total Protein

Six Sigma

Six Sigma

Transferrin

 

Six Sigma

Triglycerides

Six Sigma

Six Sigma

Urea Nitrogen

 

Four Sigma

Uric Acid

Six Sigma

Six Sigma

Immunoassay

Verified on i2000 A

AFP

Five Sigma

CEA

Four Sigma

hCG

Four Sigma

PSA

Six Sigma

T3, Total

Six Sigma

T4, Total

Six Sigma

TSH

Four Sigma

 

Immunoassay

Verified on i2000 B

Cortisol

Four Sigma

Ferritin

Five Sigma

FSH

Six Sigma

LH

Four Sigma

Progesterone

Four Sigma

Prolactin

Five Sigma

 

Six Sigma: World Class Quality. Possible to use 3s to 3.5s limits and a minimum of controls

Five Sigma: Excellent Quality. Possible to use 3s limits or a 1:3s/2:2s/R:4s Westgard Rule

Four Sigma: Good Quality. Possible to use 1:3s/2:2s/R:4s/4:1s Westgard Rule

 Visual Summary of Performance of Loh Guan Gye chemistry and immunoassays

 2017 Re VP LohGuanLye CC A NMEDX

 2017 Re VP LohGuanLye CC B NMEDX

2017 Re VP LohGuanLye IA A NMEDX 

2017 Re VP LohGuanLye IA B NMEDX

Congratulations to the Loh Guan Lyelaboratory staff.

 

Let us know what you're interested in!
Please use this form to request more infromation about 

Westgard Products and Services.

Invalid Input
Invalid Input
Invalid Input
Invalid Input